MAMORAY HDR-C

Single-sided orthochromatic mammography film that provides the contrast needed for viewing breast tissue and clinical information.

Key benefits

  • Optimal dynamic range for optimized view of varying density areas.
  • Split Emulsion Layer technology providing two separate emulsion layers.
  • Cubic Crystal technology, minimizing noise on the image caused by inherent graininess and improving processing consistency.
  • Comfortable cool blue image tint, thanks to the silver crystal structure.

MAMORAY HDR-C is a single-sided orthochromatic mammography film

Can be used with following products and services

G138i developer and G334i HD fixer are strongly recommended.

MAMORAY HDR-C can be combined with MAMORAY HD, MAMORAY HD-S or MAMORAY Detail R screens.

Suitable for following market segments

MAMORAY HDR-C film is designed for standard RP processing.

Availability

Worldwide.

Two emulsion technologies working together

MAMORAY HDR-C film uses two emulsion technologies working together: Split Emulsion Layer (S.E.L.) and Cubic Crystal technologies. The Split Emulsion Layer technology provides the film with two separate emulsion layers on one side of the film. Each layer consists of monodispersed Cubic Crystals: cubic silver crystals of identical size. These crystals minimize the noise on the image.

MAMORAY HDR-C (high dynamic range - contrast) film is designed for standard rapid (RP) processing and uses two emulsion technologies working together: Split Emulsion Layer (S.E.L.) and Cubic Crystal technologies, which results in an unmatched mammography image quality.

MAMORAY HDR-C provides the best results in combination with MAMORAY screens and cassettes. The use of G138i developer and G334i HD fixer are strongly recommended.



Two separate emulsion layers

The first S.E.L. emulsion layer provides high contrast in the breast parenchyma and improved visualization of clinically-significant information in dense tissue. The second emulsion layer provides you with a high maximum density, which enhances the visualization of subcutaneous and retro-glandular areas, especially in radio-dense breasts.


High dynamic range

MAMORAY HDR-C performs well for mammography imaging due to its high dynamic range. The sensitometric curve supports the visualization of the varying densities found within the breast, providing optimized contrast at each density.


Consistent results and ease-of-use

Cubic Crystals develop rapidly, improving the consistency of your processing. The normal fluctuations in the processing conditions have hardly any effect on the sensitometric results of the MAMORAY HDR-C film. The optimized silver crystal structure of MAMORAY HDR-C results in a neutral image tint, which makes reading images easier and more comfortable; reduces eye fatigue; and maximizes the ability to visualize small details and fine structures within the breast.

Processing conditions MAMORAY HDR-C film

MAMORAY™ HDR-C: Processing conditions

1 Available on all E.O.S. processing equipment. There are 3 settings: on, off and auto. On means that there is always a minimum amount of developer added to the developer tank. Auto means that the jog cycle is switched on, which indicates that less than 3 m2 (about 75 films) was processed the day before.

2 Available on all E.O.S. processing equipment. Every time the processor is started, one fourth of the developer is replaced.


Available MAMORAY Cassette sizes

MAMORAY™ HDR-C: Available MAMORAY Cassette sizes


MAMORAY intensifying screen combinations

MAMORAY™ HDR-C: MAMORAY intensifying screen combinations


MAMORAY HDR-C FILM

Storage conditions

• Temperature: 4-25 °C/39-77 °F

• Relative humidity: between 30-50%


Operating conditions

• Temperature: 15-25 °C/60-77 °F

• Relative humidity: between 30-50%

• Shield the film from heat and all penetrating radiation, which might fog the film.


Recommended chemicals

• G138i developer and G334i fixer are strongly recommended


Recommended developer temperature

• Developer temperature: 34 °C (95 °F)



MAMORAY CASSETTES

Safety compliance

• DIN 6832 part 2 and 3, ANSI PH 1.49, IEC 406



MAMORAY SCREENS

Recommendations

• Protect MAMORAY screens from humidity

• Do not expose to sunlight or ultraviolet rays, that may result in discoloration or warping.

• Immediately remove dust and stains from the screens


Cleaning

• Only use Agfa screen cleaner to clean the MAMORAY screens

• Moisten a piece of gauze with the cleaner

• Gently wipe the screen surface

• After cleaning, dry the screen using a clean piece of gauze

• Leave the cassette open for drying before reloading it with film

Filmdoos